Commercial & Industrial Standard Rebates

Laclede offers Commercial and Industrial (C&I) customers standardized rebates for qualified high-efficiency equipment installations and services. Table 1 provides an Apply Online option, required forms for specific types of applications and downloadable paper applications. Table 2 provides a list of available Standard rebates along with requirements and rebate amounts. Energy-saving improvements not listed, may be eligible for rebates under the Laclede Custom Program.

Ready to Apply? It’s Easy! Review the program Terms and Conditions and then choose the application option that's right for you.

Table 1

Apply Online or download a Paper Application Form. Depending on the type of rebate application, please download, complete and submit the required form with your online application.

Type of Rebate Additional Required Forms (Download, complete and submit with application) Online Application Paper Application Forms
HVAC System and Components N/A Apply Online HVAC System and Components Application
Boiler System and Components N/A Boiler System and Components Application
Boiler Tune-up Boiler Tune-up Worksheets Boiler Tune-up Application
Steam Trap Steam trap Survey Steam Trap Application
Water Heating System N/A Water Heating System Application
Food Service Equipment N/A Food Service Equipment Application
Online Applications Only: If you will be requesting your rebate check to be made payable to a Third-party recipient, download, complete and submit the Third-party Authorization Form with your online application.

Have a Question? Call one of our rebate coordinators at (800) 426-5784, (302) 504-3084 or email us at Laclede-MGE@appliedenergygroup.com


Table 2

Equipment or Service Minimum Efficiency/Requirement Rebate
HVAC System & Components
Gas Furnace 92% AFUE $200 per unit
Gas Furnace 94% AFUE $250 per unit
Low-Intensity Infrared Heater Electronic Ignition / Interior Installation Only $300 per unit
Condensing Unit Heater 90% Thermal Efficiency (TE) $300 per unit
HTHV Direct-Fired Gas Heater 90% Thermal Efficiency (TE) $500 per unit
Programmable thermostat 7-Day Programmable 50% of unit cost up to $40 per unit
Boiler Heating System & Components
Gas Boiler (Hot Water)
 
≤ 300,000 Btu/h: 85% AFUE Up to $750 per unit
>300,000 to <1,000,000 Btu/h: 83% TE Up to $1,500 per unit
≥1,000,000 Btu/h: 83% TE Up to $3,000 per unit
  Exact Hot Water Boiler Rebates are determined based upon size and efficiency
Gas Boiler (Low Pressure Steam ≤ 15 PSIG)
 
≤300,000 Btu/h: 83% AFUE Up to $750 per unit
>300,000 to <1,000,000 Btu/h: 83% TE Up to $1,500 per unit
≥1,000,000 Btu/h: 83% AFUE Up to $3,000 per unit
  Exact Low Pressure Steam Boiler Rebates are determined based upon size and efficiency
Gas Boiler (High Pressure Steam > 15 PSIG)
 
≤300,000 Btu/h: 81.5% AFUE Up to $750 per unit
>300,000 to <1,000,000 Btu/h: 81.5% TE Up to $1,500 per unit
≥1,000,000 Btu/h: 81.5% TE Up to $3,000 per unit
  Exact High Pressure Steam Boiler Rebates are determined based upon size and efficiency
Continuous Modulating Burner Retrofit to Existing Boiler Only 25% of equipment cost up to $15,000 per burner
Vent or Primary Air Damper Retrofit to Existing Boiler Only 50% of the equipment cost up to $500 per boiler
Advanced Load Monitoring (ALM) Boiler Control Retrofit to Existing Hot Water Space-Heating Boiler Only $2000 per control
Outdoor Temperature Reset (OTR) Boiler Control Retrofit to Existing Hot Water Space-Heating Boiler Only $200 per control
Boiler Tune-up
Gas-Fired Boiler Tune-up
  • Eligible for tune up every two years
     
  • Completed Checklist
     
  • Flue-Gas tape(copy) or results
50% of installed cost up to $500 per boiler
Gas-Fired Boiler Tune up (Non- Profit Customers*)
  • Eligible for tune up every two years.
     
  • Completed Checklist
     
  • Flue-Gas tape(copy) or results
75% of installed cost up to $750 per boiler
Steam Trap
Steam-Trap Replacement
  • Maximum of 25 failing traps per program year
     
  • Must include steam-trap survey/failure study report.
50% of the equipment cost up to $2,500 per program year
Water Heating Equipment
Gas Condensing Storage Water Heater >75,000 to ≤500,000 Btu/h input
90% TE
$250 per unit
Gas Instantaneous Water Heater (< 2 gal.) .82 EF $300 per unit
Food Service Equipment
Steamer ENERGY STAR® qualified 50% of the equipment cost up to $475 per unit
Fryer ENERGY STAR® qualified 50% of the equipment cost up to $350 per unit
Griddle ENERGY STAR® qualified. 
(Top and bottom surfaces of clamshell models must be gas)
50% of the equipment cost up to $400 per unit
Convection Oven ENERGY STAR® qualified 50% of the equipment cost up to $200 per unit
Combination Oven ENERGY STAR® qualified 50% of the equipment cost up to $500 per unit
Conveyor Oven New oven with baking efficiency > 42%. Idle energy consumption rate < 57,000 Btu/h utilizing ASTM standard F1817. 50% of the equipment cost up to $300 per unit
Rack Oven - single rack New oven with baking efficiency ≥ 50% utilizing ASTM standard 2093. 50% of the equipment cost up to $500 per unit
Rack Oven - double rack New oven with baking efficiency ≥ 50% utilizing ASTM standard 2093. 50% of the equipment cost up to $1000 per unit
Infrared Charbroiler Natural gas charbroiler with infrared burners** ASTM compliant 50% of the equipment cost up to $300 per unit
Infrared Salamander Broiler Natural gas salamander broiler with infrared burners** ASTM compliant 50% of the equipment cost up to $200 per unit
Infrared Rotisserie Oven Natural gas rotisserie oven with infrared burners** ASTM compliant 50% of the equipment cost up to $300 per unit
Kitchen Demand Control Ventilation (KDCV) KDCV control system must utilize variable
frequency drives and sensors to vary exhaust and/or gas-fired make-up air flow(s). Natural Gas heating required within kitchen space.
$300 per system
Low Flow Pre-Rinse Spray Nozzle
  • Replacement Only
     
  • GPM rating of 1.6 or less
     
  • Maximum Two Nozzles
50% of equipment cost up to $100 per nozzle

AFUE = Annual Fuel Utilization Efficiency, EF = Energy Factor, TE = Thermal Efficiency. Ratings are provided by the manufacturer and can be found at: www.ahridirectory.org
*Non-Profit Customers are defined as government agencies, public school districts, or other customers that demonstrate qualification as a 501(c) (3) charity or benevolent corporation as defined by RSMo 352.010.